Installation
GB
! Before operating your new appliance please read
this instruction booklet carefully. It contains important
information concerning the safe installation and
operation of the appliance.
! Please keep these operating instructions for future
reference. Make sure that the instructions are kept with
the appliance if it is sold, given away or moved.
! The appliance must be installed by a qualified
professional in accordance with the instructions
provided.
! Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected
from the electricity supply.
Positioning and levelling
! It is possible to install the appliance alongside
cupboards whose height does not exceed that of the
hob surface.
! Make sure that the wall in contact with the back of
the appliance is made from a non-flammable, heat-
resistant material (T 90°C).
To install the appliance correctly:
• Place it in the kitchen, the dining room or the bed-sit
(not in the bathroom).
• If the top of the hob is higher than the cupboards,
HOOD
600
Min.
mm.
This distance should be increased to 700 mm if the wall
cabinets are flammable (see fi gure).
• Do not position blinds behind the cooker or less than
200 mm away from its sides.
• Any hoods must be installed according to the
instructions listed in the relevant operating manual.
Levelling
If it is necessary to level the appliance, screw the
18
All manuals and user guides at all-guides.com
the appliance must be
installed at least 600 mm
away from them.
•
If the cooker is
installed underneath a
wall cabinet, there must
be a minimum distance
of 420 mm between this
cabinet and the top of
the hob.
adjustable feet into the places
provided on each corner of the
base of the cooker (see fi gure).
The legs* fit into the slots on the
underside of the base of the
cooker.
Electrical connection
Fitting the power supply cable
To open the terminal board:
• Insert a screwdriver into the side tabs of the terminal
board cover.
• Pull the cover to open it.
clamp screw and the wire contact screws.
! The jumpers are pre-set at the Factory for 230 V
single-phase connection (see fi gure).
230V ~
H05RR-F 3x4 CEI-UNEL 35363
H05VV-F 3x4 CEI-UNEL 35746
N
L
• To carry out the electrical connections as shown in
the figures, use the two jumpers inside the box (see
fi gure - labelled "P").
N
L1
*
Only available in certain models.
To install the cable,
follow the instructions
below:
•
Loosen the cable
P
L2
L3