Full Programming Options
Quickstart
>
Tel. Numbers >
Alarm no. 1
Alarm no. 2
Alarm no. 3
Alarm no. 4
Tech.no.
Background no.
Call attempts
Settings
>
Codice ID
Volume
Accessories >
System Config >
System Config+ >
HW Monitoring >
Lift Monitor
IP1 only
iP1+iP2 (Serv.)
Service Count
Interval
Live Count
Delays
>
COP delay
MPS delay
TOC delay
Tech IP1 delay
Tech IP2 delay
Hangup delay
Answer delay
Messages
>
Location
Reassurance
Guidance
Time / Date >
Time
Date
Advanced
>
Passcode
Network ID
Next EN81 call
PBX Frequency
Language
Relay Mode
Relay Override >
HW Config >
GMT Offset
DTMF RX
Menu Sections continued...
Settings
Codice ID
If using Memco GlobalNet to monitor the Memcom
following:
[3 digit customer number][Unit ID code]
Volume
Press the up and down arrows to adjust the volume and press # to
confirm.
Accessories
Accessories >
System Config
System Config >
>
>
External mic
Set to 'ü' as default. De-select this
option if you are not using the external
microphone
COP Accessory
Select this option if connecting the
Memcom
+
to an Avire COP accessory
Memco GSM
Select this option if connecting the
Memcom
+
to a memco GSM with part
number 452 000
Multi-dial
Sets the unit to call each of the
programmed alarm numbers one after
the other.
EN81-28 Mode
Prevents the unit from accepting
incoming calls when not in an alarm
state and requires a passcode to enter
remote programming.
Consec. dial
Changes the dialling sequence; all
call attempts to the first number are
completed before unit attempts to call
the second number and so on.
Ext. mic. record
Only use if directed by Avire Technical
Support
Alt. dial tone
Allows system to work with an
intermittent dial tone.
TOC int. mic.
This option activates the internal mic
on the Memcom
calls form the unit or during MPS calls.
Required if the External Mic does not
clearly pick up speech from the TOC
position.
Verbal c/down
Units gives a verbal countdown until
the emergency call is placed.
N/C alarm push
Select option if connecting to a N/C
alarm push contact
Service as alm
Select option if connecting to an alarm
push with voltage to connections
16 & 17
Passcode?
Require a passcode to be entered
before accessing the 'System Config'
menu.
EOA Pictogram
Sets the system to keep the alarm
pictogram lit whilst the unit is in an
alarm state.
Alarm Tone
Sets the unit to emit a tone from the
internal speaker when the alarm push
is pressed.
enter the
+
+
unit during alarm
7