INSTRUCTION FOR USE
EN
1. Clean the print object for 3 min in a reusable ethanol solution (96 %) in an unheated
ultrasonic bath.
2. The precleaned print object must be cleaned thoroughly for 2 min using a fresh ethanol
(96 %) solution. The print object is then removed from the ethanol bath and sprayed with
additional ethanol (96 %) in order to fully rinse off any remaining resin residue.
Tip: Resin residues can also be removed using a brush soaked in ethanol (96 %).
The entire cleaning process should not take longer than 5 minutes as this could otherwise
have a detrimental effect on the print objects. After cleaning, the print object is dried using
compressed air, if possible under suction. If there is liquid resin still adhering to the print
object, this can be completely removed by spraying again with ethanol (96 %) and re-drying.
Finishing
Following this, the support structures, if present, are removed. To this end, either a
cutting wheel or side cutters can be used. It must be ensured that the printed object is not
deformed! The completely cleaned print objects must be post-cured to attain the required
material properties.
The final properties of the print object depend on the post-curing process. The final material
properties are achieved using a light polymerisation unit with the following performance
data: two xenon stroboscopic lamps, flash frequency 10 Hz, light spectrum 300–700 nm
(e.g., BEGO Otoflash) or one xenon stroboscopic lamp, flash frequency 20 Hz, light spectrum
390–540 nm (e.g., HiLite Power, Heraeus Kulzer).
VarseoWax Model
Post-curing device
Flash
Time [seconds]
Note: The times given only apply to regularly maintained equipment that guarantees a
corresponding light intensity.
7. Storage and transportation of printed objects
The fully cured print objects are ideally stored and transported at room temperature and away
from light in a suitable, light-tight transport box!
When not being used or when being stored by the user, the models must be stored away from
light to prevent changes in form!
BEGO Otoflash
2 x 2,000
HiLite Power
Note
Please turn between the two
curing procedures
2 x 180