Safety Related Data - DOLD SAFEMASTER STS ZRX Serie Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Related Data

Data suitable for the PFH
summation method according to
D
EN ISO13849-1:2016
Data
according
to EN
Locking Module ZRX, ZAX and ZRH
ISO13849-
1:2016
Category
2
PL
d
PFH
1,061E-09
6,84592E-10 5,44569E-10 1,00122E-10
D
T
20
10D
CCF
65-100
required
B
2.000.000
10d
d
(d/a)
365
op
h
(h/d)
24
op
t
(h)
1
cycle
n
8760
op
Diagnostic
60%
coverage DC
Test interval
according to
1 / year
ISO14119
Category 2: The prerequisites for installation and integration into a
category 2 architecture must be met
Category 3: The prerequisites for installation and integration into a
category 3 architecture must be met
Category 4: The prerequisites for installation and integration into a
category 4 architecture must be met, in particular 2
actuators must be used
PFH
:
A single module has no function. As a result, an individual
D
module cannot have any safety-related characteristic values.
The safety-related characteristic data in the table only serve
to determine the values of a unit into which it is integrated.
When used as part of a key transfer system:
- PFH
total STS system = SUM PFH
D
- Lowest category of a module = category of whole
STS system
- Lowest DC of a module = DC entire STS unit
!
If the design of a unit is changed, the safety-related data may also
change.
3
3
d
e
20
20
85-100
85-100
2.000.000
2.000.000
2.000.000
365
365
24
24
1
1
8760
8760
60%
90%
1 / year
1 / month
1 / month
+ ... PFH
D1
4
e
20
85-100
365
24
1
8760
99%
Dn
13
SAFEMASTER STS Locking module ZRX, ZAX and ZRH / 10.07.20 en / 271A

Publicité

Table des Matières
loading