Installation
Masonry Chimney & Fireplace
The oven may also be connected to a masonry chimney, provided the
chimney complies with the construction rules found in the building code
enforced locally. To ensure that a masonry chimney meets the minimum
standards of the National Fire Protection Association (NFPA) it should
be inspected by a professional to make sure there are no cracks, loose
mortar or other signs of deterioration and blockage. Also have the chimney
cleaned before the oven is installed and operated.
Figure 7
Ceiling joist
Floor
protection
12
Masonry chimney requirements
Concrete cap
Combustible wall
Thimble -
12" of brick
Rafter
Fireclay flue
liner with
airspace
Flashing
Eave
Clearance
18" minimum
Sheathing
Airtight
clean
door
www.nectre.com/usa-nectre