Installation
Figure 5B
Flue pipe attachment
Male Part Downwards
This prevents any amount of
condensed or liquid creosote from
running down the outside of the
pipe or the oven top. All joints,
including the flue collar connection
must be secured with three sheet
metal screws to ensure that the
sections do not separate.
For the best performance, the
chimney connector should be as
short and direct as possible, with
no more than two 90° elbows. The
maximum horizontal run is 36"
(915 mm) and a recommended
total length of flue pipe should not
exceed 10 feet (3.0 m). Always
slope horizontal runs upward
¼" per foot (0.3 m) toward the
chimney.
No part of the chimney connector
may pass through an attic, roof
10
1/4" slope per foot
3 screws
space, closet, other concealed space
or through a floor or ceiling. All
sections of the chimney connectors
must be accessible for cleaning.
Where passage through a wall or
partition of combustible construction
is desired, the installation must
conform to NFPA 211 or CAN/
CSA-B365, and is also addressed
in this manual.
Chimney Requirements
WARNING: Do not connect this
wood-fired oven to a chimney flue
serving another appliance.
WARNING: Do not connect to
any air distribution or duct system.
This oven must be connected to a
6" (152 mm) factory built UL 103 HT
chimney (ULC S629, in Canada)
or a code - approved masonry
chimney with a flue liner.
An effective vapor barrier at the
location where the chimney or
component penetrates to the
exterior of the structure must be
maintained as per the installer's
complying method.
www.nectre.com/usa-nectre