7 MAINTENANCE

(by an enabled technical service centre)
7.1 MAINTENANCE
The stove may only be maintained by an enabled
technical service centre.
Prior to effecting any maintenance operation,
adopt the following precautions:
-
Make sure that the stove is completely cold.
-
Make sure that the ashes have gone out
completely.
-
Use the personal protective equipment specified
in Directive 89/391/EEC.
-
Make sure the mains power is off at the master
power switch.
-
Ensure that the power supply cannot be
restored accidentally. Remove the power plug
from the socket.
-
Always use proper tools.
-
Once maintenance or repair activities are
completed, reinstall all the protections and
reactivate all the safety devices prior to
restarting the system.
7.1.1 Servicing the flue system
This must be done at least once a year, or every 4
tons of pellets.
If the flue has any horizontal sections, remove any
ash and soot before they can block the flue itself.
If it is not kept clean, the stove may experience
problems including:
-
poor combustion
-
blackened glass
-
blocked brazier, accumulated ash and pellets
-
ash and excessive encrustations on the heat
exchanger, which lower its efficiency.
INSTALLATION
7.1.2 Servicing the stove
This must be done at least once a year, or whenever
the stove itself displays the maintenance required
message.
The technician must:
-
-
-
-
-
-
-
7.1.3 Cleaning the exhaust duct flue of the stove
At least once a season you must remove the right
side of the stove and clean with an ash vacuum
and a brush, the smoke box. To do this you need
to access the compartment by removing the two
inspection plugs as shown in Figure (7.1)
00 477 5831 - 04/04/2019 - PN - Italy
thoroughly clean the fumes circuit
check the condition and tightness of all seals
check the condition and cleanliness of all
internal components
check the tightness and cleanliness of the
connection of the flue to the stove
remove all pellet residue remaining in the pellet
tank
check that the stove is operating properly
reset any warnings and alarms (the manual
reset thermostats are at the back of the stove
next to the power cable outlet).
fig. 7.1