Discharge Through Roof Using A Traditional Chimney - CASATELLI TOMMASO G Manuel D'installation Et D'entretien

Masquer les pouces Voir aussi pour TOMMASO G:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5.5.1 Discharge through roof using a traditional chimney

The chimney used to discharge the flue gas must
be made in accordance with standards UNI 10683
- EN 1856-1-2 - EN 1857 - EN 1443 - EN 13384-
1-3 - EN 12391-1 both as regards the dimensions
and the construction materials used.
DAMAGED chimneys made from unsuitable
material (asbestos cement, galvanised steel,
etc.... with a rough and porous inside surface) are
prohibited by law and affect proper stove operation.
The flue gas can be discharged through a traditional
chimney (Fig. 5.8) as long as you make sure on the
state of maintenance of the chimney.
For larger chimneys, suitably insulated steel
pipes need to be inserted on the inside (diameter
according to the length) (Fig. 5.9).
Makes sure connections to brick chimneys are
suitably sealed.
If the flues run through wooden roofs or walls,
special certified pass-through kits need to be used,
available on the market.
1) Vermiculite and/or rock wool.
2) Steel pipes.
fig. 5.7
3) Closure panel.
24
INSTALLATION
fig. 5.8
A) Chimney pot with wind protection
B) Seal
C) Inspection
fig. 5.9
00 477 5831 - 04/04/2019 - PN - Italy
≥ 40 cm
≥ 40 cm
1
2
3

Publicité

Table des Matières
loading

Table des Matières