Changing/ Adding Oil
You should check the oil level of your generator according to the maintenance schedule
in figure 13. When the oil level is low you will need to add oil until the level is sufficient
to run the generator.
The oil capacity of your generator engine is listed in figure 14.
It is only necessary to drain the oil from the crankcase if it has become contaminated
with water or dirt. In this case, you can drain the oil from the generator according to the
following steps:
1. Place a bucket underneath the generator to catch oil as it drains.
2. Remove the back cover of the generator.
3. Using a 10 mm hex wrench, unscrew the oil drain plug, which is located on the
crankcase underneath the oil filler/dipstick cap (see figure 13). Allow all the oil to
drain from the generator.
4. Replace the oil drain plug and tighten with a 10 mm hex wrench.
To add oil to the crankcase, follow these steps:
1. Make sure the generator is on a level surface.
2. Unscrew the oil filler/dipstick cap from the engine as shown in figure 14 above.
3. Using a funnel, add high detergent motor oil to the crankcase. We recommend
SAE 30W
come close to the top of the oil fill opening (see figure 16).
76 76 76 76 76
Figure 13- Checking the oil
Model number
Engine oil
capacity
Figure 14- Engine Oil Capacity.
4-stroke motor oil for general use. When full, the oil level should
If any fuel in th