5.1 Steps of Using the generator
1.Start the engine and make sure the output indicator (green) comes on and other red
light are off.
2. Make sure that the appliance to be used is switched off, and plug in the appliance.
5.2 Output and Overload Indicators, low engine oil Indicator
The out indicator light (green) will remain ON during normal operating conditions.
If the generator is overloaded, or if there is a short in the connected appliance, the output
indicator light (green) will go OFF, the overload indicator light (red) will go ON and
current to the connected appliance will be cutted off.
Stop the engine if the overload indicator light (red) comes ON and check overload
reason
Check engine oil if the oil indicator (Red) turns ON.
NOTE:
Before connecting an appliance to the generator, check that it is in good order, and
that its electrical rating does not exceed that of the generator.Then connect the
power cord of the appliance, and start the engine.
When an electric motor is started, both the overload indicator light (red) and the
output indicator light (green) lights may go on simultaneously. This is normal if the
overload indicator light(red) goes off after about four (4) seconds. If the overload
indicator light(red) stays on, please contact with the dealer.
5.3 Low oil alert system
The low oil alert system is designed to avoid the damage of engine due to insufficient oil
inside the crankcase. The low oil alert system is actuated and automatically shut off the
engine when the oil level is about to be lower than the safety level. When the low oil alert
system is actuated, low oil indicator (Red) flashes if the operator attempts to start the
engine again, in this case the engine could not be started. ADD OIL!
73