Ferroli ECOTRONIC HITECH Instructions De Montage Et D'utilisation page 196

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

System with one tank, one circulating pump and three probes.
(Modulating circulating pump, no metering, with excess heat dissipation).
- Assigning of terminals and block diagram.
S4 S4 - V1 S3 S3 S2 S2 S1 S1
S1
/
P1
/
256
/
/
/
/
/
/
Symbol Description
F Fuse
P1 Solar circulating pump
R Relay
S1 Probe PT 1000 Solar collector
S2 Probe PT 1000 Lower tank
196
EN
/
/
/
/
/
/
/
/
/
/
/
/
Bi
M
/
/
B
N
/
/
/
/
/
/
/
/
/
code 3542A420 - Rev. 00 - 12/2021
R3 R3 R2 N L N R1 N
/
/
/
/
/
/
R
/
/
/
S3
S2
/
/
/
/
Symbol Description
S3 Probe PT 1000 Upper tank
T1 Consent for excess heat dissipation
256 Modulating circulating pump signal
ECOTRONIC HiTech
/
/
/
/
230 Vac
/
/
/
/
/
/
/
/
/
L
N
F
NC
NA
C
/
/
/
/
/
/
/
T1

Publicité

Table des Matières
loading

Table des Matières