Display Symbols; Description Of Controls - ESBE TPW114 Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
WARNING
- To adjust properly room temperature, install the thermostat
far from heat sources, airstreams or particularly cold walls
(thermal bridges).
- In order to grant the electrical safety, it is mandatory to
screw the chronostat body to the wall mount plate through
the two screws supplied which must be mounted in the
battery holder.
- If the load controlled by the relay of the chronostat operates
with mains voltage, the connection must be made via an
omnipolar switch complying with current standards and with
a contact opening of at least 3 mm in each pole.
- Installation and electrical wirings of this appliance must be
current standards.
- Before wiring the appliance be sure to turn the mains power
off.
The device is designed to be installed in a standard recess (or wall)
mounted junction box with two or three modules or else directly on
the wall using the screw anchors provided.
To install the device carry out the following steps:
1
chronostat as shown in Fig. 1.
Fig. 1
Fix the plate directly on the wall or onto 2 or 3 module junction
2
boxes by means of the two holes for screws (distance between
centres: 60 mm or 85mm), taking care to pass the wires
through the opening as shown in Fig. 2.
Fig. 2
Make electrical wirings by passing the wires through the
3
rectangular opening in the wall plate (Fig. 2), and according to
thediagram in Fig. 3.
LOAD
RED
BLACK
REMOTE
SENSOR
Fig. 3
Connect the remote sensor (if present) or the phone interface
to connector 'B' shown in Fig. 4. The load must be wired to
terminal block 'A' shown in Fig. 4.
A
B
Fig. 4
TCW02B0001EV 027377 240816
4
of the base with the relevant holes of the plate and then exert
a pressure on the device to the left side until the plastic teeth
of the plate snap.
1
Fig. 5
Secure the bodyof the programmable thermostat to the wall
5
plate using the supplied screw that is located inside the battery
compartment (Fig.6).
2
1
Fig. 6
Insert the batteries in the battery compartment (I
6
see paragraph ' HOW TO INSERT/REPLACE THE BATTERIES '.

DESCRIPTION OF CONTROLS

I
F
H
LEGEND
A
Button with double function:
- In normal operation: activates the function 24 hours Manual /
WHITE
Permanent Manual / Automatic.
TELEPHONE
- In schedule programming: sets the regulation temperature into
INTERFACE
Economy mode.
B
Button with double function:
- In normal operation: turns on and off the chronostat.
- In schedule programming: sets the regulation temperature into Off /
Antifreeze mode.
C
Button with triple function:
- In normal operation: displays current time or temperature.
- In schedule programming: sets the regulation temperature into
Comfort mode.
- In 'Set-Point temperatures settings', shows either the Comfort or the
Economy temperature
D
(increasing the value).
E
(decreasing the value).
F
Gives access to the user parameters list.
G
Button with double function:
- In normal operation updates the values sampled by the thermostat.
- In 'User parameters settings', enables the selected parameter
H
I
Battery compartment
G
3

DISPLAY SYMBOLS

In the following is explained the meaning of some symbols which may
appear on the display:
Battery status indication.
Flashing:
Batteries discharged; replace batteries.
Temperature regulation in Comfort mode.
Temperature regulation in Economy mode.
Temperature regulation in Off / Antifreeze mode.
Chronostat off: antifreeze function active, the display shows
'OFF'.
Heating mode enabled.
Cooling mode enabled.
24h
Temperature regulation in Comfort mode for 24 hours.
Permanent temperature regulation in Comfort mode.
Fixed: shows access to the user parameters
P
Flashing
Flashing: Cleaning program active (the remaining time is
shown on the display).
Flashing: Vacation program active (the remaining time is
shown on the display).
Fixed: Indicates that the telephone interface is active.
Flashing:
Indicates that the remote command received by the
telephone interface has been overridden by another local
request through the chronostat buttons.
Fixed:
The temperature shown on the display is the one measured by
the internal sensor, yet the temperature regulation takes place
according to the remote sensor.
Flashing:
Both temperature shown and room temperature regulation refer
to the internal sensor.
Fixed:
The temperature shown on the display is the one measured by the
remote sensor, yet the temperature regulation takes place according
to the internal sensor.
Flashing:
Both temperature shown and room temperature regulation refer to
the remote sensor.
QUICK GUIDE FOR SETTING THE TIME SCHEDULE
A
Press button '
'.
B
The display shows ' PrOG ' with the icon '
Press key ' OK ': the display shows the word ' dAY ', the icon
C
'
D
P
Press buttons '
' and '
' in order to choose one of the four
E
days combinations available as pre-set.
Press button ' OK
The display shows hour 00:00 with the relevant dash, in the upside
Press one of the following buttons to select the temperature
regulation level desired:
Comfort mode:
Press the '
Off / Antifreeze:
Press the '
Economy mode:
Press the ' ' button.
Moving the time cursor: Press button '
Each time the button which sets the regulation mode is depressed,
the time cursor automatically jumps into the next half hour.
Once the time schedule for the day or group of days selected has
been set, press button ' OK '.
The display will show the time schedule for the next day or group
of days until the whole week has been covered.
Once the time schedule for the whole week has been set, press
button ' OK '. The chronostat will store the program into its
memory and the word ' MEMO ' is shown on the display, then it
will automatically quit the time schedule setting procedure.
www.esbe.eu
' turned on.
P
' button.
' button.
' or '
'.
- ENGLISH -

Publicité