LOCATION
The equipment area must be kept free and clear of combustible substances.
This broiler is design certified for installation with the following minimum clearances from combustible
and noncombustible adjacent wall construction:
MODELS
GHCB40
GHCB40C
GHCB44
MODEL
GHIR44
MODEL
HCB2
MODEL
IR2
The installation location must allow adequate clearances for servicing and proper operation. A
minimum front clearance of 35" (889 mm) is required.
Do not obstruct the flow of combustion and ventilation air. Adequate clearance for air openings into
the combustion chamber must be provided. Make sure there is an adequate supply of air in the room
to replace air taken by ventilating systems and allow for combustion gas at the broiler burners.
CONSTRUCTION
Back
Right Side
Left Side
Floor
CONSTRUCTION
Back
Right Side
Left Side
Floor
CONSTRUCTION
Back
Right Side
Left Side
Floor
CONSTRUCTION
Back
Right Side
Left Side
Floor
– 5 –
COMBUSTIBLE
6" (152 mm)
6" (152 mm)
6" (152 mm)
6" (152 mm)
COMBUSTIBLE
4" (102 mm)
0"
0"
6" (152 mm)
COMBUSTIBLE
4" (102 mm)
4" (102 mm)
4" (102 mm)
6" (152 mm)
COMBUSTIBLE
4" (102 mm)
0"
0"
6" (152 mm)
NONCOMBUSTIBLE
CONSTRUCTION
0"
0"
0"
0"
NONCOMBUSTIBLE
CONSTRUCTION
0"
0"
0"
0"
NONCOMBUSTIBLE
CONSTRUCTION
0"
0"
0"
0"
NONCOMBUSTIBLE
CONSTRUCTION
0"
0"
0"
0"