Adjusting The Nailing Depth - Hitachi NR 83A2 Y Manuel D'instructions Et De Sécurité

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
NOTE:
● If all warnings and instructions are followed, safe
operation is possible with two systems: SINGLE
SEQUENTIAL ACTUATION MECHANISM and
CONTACT ACTUATION MECHANISM.
● Always handle nails and package carefully. If nails
are dropped, collating plastic may be broken.
● After nailing:
1) disconnect air hose from the Nailer;
2) remove all nails from the Nailer;
3) supply 5 – 10 drops of Hitachi pneumatic tool
lubricant into the air plug on the Nailer; and
4) open the petcock on the air compressor tank to
drain any moisture.

ADJUSTING THE NAILING DEPTH

[Only NR83A2 (with depth adjustment)]
● Disconnect the air hose from the nailer
before turning the adjuster.
To assure that each nail penetrates to the same depth, be
sure that:
1) the air pressure to the Nailer remains constant
(regulator is installed and working properly), and
2) the Nailer is always held fi rmly against the workpiece.
If nails are driven too deep or shallow into the workpiece,
adjust the nailing in the following order.
1 DISCONNECT AIR HOSE FROM NAILER
2 If nails are driven too deep, turn the adjuster to the
shallow side.
Adjustments are in half-turn increments.
Turn Adjuster
2
Too Deep
16
WARNING
Adjuster
15
Disconnect
air hose
Flush
If nails are driven too shallow, turn the adjuster to the
deep side.
Turn Adjuster
2
Too Shallow
3 Stop turning the adjuster when a suitable position is
reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR EYE PROTECTION.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
Flush

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nr 83a2 s1

Table des Matières