Application Examples - DOLD SAFEMASTER LG 7928 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Application Examples

L1(+)
A1(+)
S11
S12
S21
LG5925
A2
N(-)
LG 5925 with LG 7928, cross fault detection, suitable up to SIL 2, Performance Level d, Cat. 3
L1(+)
A1(+)
S11
S12
S21
LG5925
A2
N(-)
LG 5925 with LG 7928, non cross fault detection, suitable up to SIL 2, Performance Level d, Cat. 3
L1(+)
Emergency
stop
A1(+)
S11
S12
S21
S22
LG5925
A2
N(-)
LG 5925 with two LG 7928, non cross fault detection, suitable up to SIL 2, Performance Level d, Cat. 3
E. Dold & Söhne GmbH & Co. KG • D-78120 Furtwangen
dold-relays@dold.com • www.dold.com
...
S22
S33
S
4 3
13
23
...
K1
...
K2
...
4 1
4 2
S22
S33
S34
13
23
...
...
K1
...
K2
...
14
24
...
S33
S34
13
23
A1(+)
...
K1
cross fault detection
not cross fault detection
...
K2
...
14
24
A1(+)
S
1 1
S21
LG7928
K1t
Cross fault detection
Not cross fault detection
K2t
2 A
1 Y
Y2
A1(+)
S11
S21
LG7928
K1t
Cross fault detection
Not cross fault detection
K2t
A2
Y1
Y2
S11
S21
17 27 37
45
LG7928
K1t
K2t
A2
Y1
Y2
18 28 38
46
Bregstraße 18 • Phone +49 7723 654-0 • Fax +49 7723 654356
16
17 27 37
45
55
18 28 38
46
6 5
M10224_b
17 27 37
45
55
18 28 38
46
56
M10225_b
55
A1(+)
S11
S21
LG7928
K1t
cross fault detection
not cross fault detection
K2t
56
A2
Y1
Y2
17 27 37
45
55
18 28 38
46
56
M11304
LG 7928 / 29.04.21 en / 390A

Publicité

Table des Matières
loading

Table des Matières