When working overhead or on vertical sur-
faces, the coolant container must not be used.
Use Slugger Cutting Paste instead. Liquids
penetrating your electric power tool may-
cause electric shock.
Avoid touching the drilled core that is auto-
matically ejected by the pilot pin when the
working procedure is finished. Contact with
the core when it is hot, or if it falls, can cause
personal injuries.
Operate the power tool only from grounded
contact sockets that comply with the specifi-
cations. Do not use any connection cables
that are damaged; use extension cables with
a grounded contact that are checked at regu-
lar intervals. A ground conductor without
continuity can cause an electric shock.
To prevent injuries, always keep your hands,
clothing, etc. away from rotating chips. The
chips can cause injuries. Always use the chip
guard.
Do not attempt to remove the cutting tool if it
still turns. This can lead to serious injuries.
Hold power tool by insulated gripping sur-
faces when performing an operation where
the cutting accessory may contact hidden
wiring or its own cord. Cutting accessory con-
tacting a "live" wire will make exposed metal
parts of the power tool "live" and shock the
operator.
Beware of any concealed electric cables, gas
or water conduits. Check the working area
before commencing work, e. g. with a metal
detector.
Do not machine any material containing
asbestos. Asbestos is cancerogenic.
Do not rivet or screw any name-plates or
signs onto the power tool. If the insulation is
damaged, protection against an electric shock
will be ineffective. Adhesive labels are recom-
mended.
Do not overload the power tool or the storage
case and do not use it as a ladder or stand.
Overloading or standing on the power tool or
the storage case can lead to the upward shift-
ing of the center of gravity of the power tool
or the storage case, and its tipping over.
Do not use accessories which are not specifi-
cally designed and recommended by the
power tool manufacturer. Safe operation is
not ensured merely because an accessory fits
your power tool.
Clean the ventilation openings on the power
tool at regular intervals using non-metal
tools. The blower of the motor draws dust
into the housing. An excessive accumulation
of metallic dust can cause an electrical hazard.
Before putting into operation, check the
power connection and the power plug for
damage.
Recommendation: The tool should always be
supplied with power via a ground fault circuit
interrupter (GFCI) with a rated current of
30 mA or less.