Dcc Protocol; Controllable Functions - LGB Nicki + Frank S. Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
DC power in the braking block. If you want this characteristic, you must do without
conventional DC power operation (CV 29/Bit 2 = 0).
mfx Protocol
Addresses
• No address is required; each decoder is given a one-time, unique identifier (UID).
• The decoder automatically registers itself on a Central Station or a Mobile Station
with its UID.
Programming
• The characteristics can be programmed using the graphic screen on the Central
Station or also partially with the Mobile Station.
• All of the Configuration Variables (CV) can be read and programmed repeatedly.
• The programming can be done either on the main track or the programming track.
• The default settings (factory settings) can be produced repeatedly.
• Function mapping: Functions can be assigned to any of the function but-
tons with the help of the 60212 Central Station (with limitations) and with the
60213/60214/60215 Central Station (See help section in the Central Station).

DCC Protocol

Addresses
• Short address – long address – multiple unit address
• Address range:
1 - 127 for short address and multiple unit address,
1 - 10239 for long address
• Every address can be programmed manually.
• Short or long address is selected by means of CV 29 (Bit 5).
• A multiple unit address that is being used deactivates the standard address.
Programming
• The characteristics can be changed repeatedly using the Configuration Variables
(CV).
• The CV numbers and the CV values are entered directly.
• The CVs can be read and programmed repeatedly. (Programming is done on the
programming track.)
• The CVs can be programmed in any order desired. (Programming can be done
on the main track PoM). The PoM can only be done with those designated in the
CV table. Programming on the main track PoM must be supported by your central
controller (Please see the description for this unit.).
• The default settings (factory settings) can be produced repeatedly.
• 14/28 or 126 speed levels can be set.
• All of the functions can be controlled according to the function mapping (see CV
description).
• See the CV description for the DCC protocol for additional information.
We recommend that in general programming should be done on the programming
track.

Controllable Functions

Lighting *
Sound effect: Long locomotive whistle
Sound effect: Operating sounds *
Sound effect: Bell
Sound effect: Station announcements
Sound effect: Short whistle blast
Sound effect: Blowing off steam
Smoke generator
Sound off/on
Engineer's cab lighting
Sound effect: Air pump
Sound effect: Coal being shoveled
Sound effect: Generator
Sound effect: Squealing brakes off
ABV, off
Low speed switching range & Double A switching light
* active in analog operation
11
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

24266

Table des Matières