Ayce JLVWB6L Mode D'emploi page 67

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

15
NOISE
Noise values measured according to relevant standard. (K = 3)
Acoustic pressure level L
Acoustic power level L
ATTENTION! The sound power level may exceed 85 dB(A), in this
case individual hearing protection shall be worn.
16
PERFORMANCE TESTING
Frequency of performance testing and inspection:
1.
Daily
Safety valve
Drain valve
2.
Weekly
Pressure tank
3.
Monthly
Intake filter
JLVWB6L (1330985)
pA
wA
Check the safety
valve for correct
operation by
pulling on the red
knob.
Check for any
visible problem .
Check for any
visible problem.
This filter should be cleaned at
least every 100 operating
hours.
The safety valve is set to the maximum
allowable pressure of the pressure tank. It is
not permitted to adjust the safety valve or
remove its seal.
It is necessary to clean this drain valve and
remove dust and dirt.
A pressure tank may not be operated if it has
defects that pose a risk to employees or third
persons.
The pressure tank should be regularly
checked for damage, such as rust.
If you discover damage, please contact the
customer service centre.
The filter can be appropriately
removed.
EN
11
|
69.9 dB(A)
89.9 dB(A)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1330985

Table des Matières