Horizontal levelling and vertical levelling
– Horizontal: Position the device on a level
surface or on a tripod.
– Vertical: Set the unit on its side feet. The
operator panel should be at the top.
– Press the "ON/OFF" switch
– The device levels itself automatically to within a range of ± 4°. During the
set-up phase, the laser flashes and the prism head remains stationary.
When levelling is complete, the laser lights up continuously and rotates at
maximum speed. Refer also to the sections about "Sensor Automatic"
and "ADS Tilt".
If the device has been placed on a surface with too much of a slope
!
(more than 4°), there is a warning sound, the prism head remains
stationary and the laser starts to flash. The device must then be
placed on a more even surface.
Positioning the vertical laser level
In vertical mode the laser level can be positioned exactly. "Sensor Automatic"
remains active and levels to the vertical laser level. Refer to the illustration
below.
!
A signal sounds when the maximum adjustment range of 4° is reached.
Manual_Centurium_Express_G_Rev20W43_DE_FR.indd 23