Technical Data; Ordering Example; Safety Related Data - DOLD SAFEMASTER STS/K M10BM/K Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Data

Mechanical Data
Mechanical principle:
Enclosure:
Internal parts:
Locking force:
Operating speed
min. / max.:
Output
Max. switching frequency:
Mechanical life:
General Data
Temperature range:
Storage temperature:
Intended use:
Mounting:
Test principles:

Ordering Example

STS- M 10 B M /K
Translatory actuator or key movement
is converted into relative movement by
mechanical components
PA + GF
Stainless steel V4A / AISI 316 / AISI 630
(acc. to EN 10027-2;
1.4401; 1.4404; 1.4542;
1.4301; 1.4310)
F
2000 N
zh
100 / 250 mm/s
360/h
1 x 10
switching cycles
6
- 25°C to + 45°C
- 25°C to + 60°C
Up to max. cat. 4, PL e according
DIN EN ISO 13849-1
According to DIN EN 50041
DIN EN ISO 13849-1:2015
DIN EN ISO 14119:2014-03
DIN EN 60947-5-1:2017
GS-ET-15:2015-05
GS-ET-19:2015-05
GS-ET-31:2010-02
FRP
End module M/K
Actuator module B/K
Key module 10/K
End module M/K

Safety Related Data

Data suitable for the PFH
summation method according
D
to EN ISO13849-1: 2016
Data
according to
EN
ISO13849-1:
2016
Category
2
PL
d
PFH
2.12199E-09 1.36918E-09 1.08914E-09 1.50183E-10
D
T
20
10D
CCF
65 ...100
required
B
2 x 10
6
10d
d
(d/a)
365
op
h
(h/d)
24
op
t
(h)
1
cycle
n
8760
op
Diagnostics
Coverage
60 %
ratio DC
Test interval
1 / year
Category 2: The prerequisites for installation and integration into a
category 2 architecture must be met
Category 3: The prerequisites for installation and integration into a
category 3 architecture must be met
Category 4: The prerequisites for installation and integration into a
category 4 architecture must be met, in particular 2
actuators must be used
PFH
:
When used as a „stand-alone unit" (not as part of a key trans-
D
fer system), the safety parameters in the table above apply
When used as part of a key transfer system:
- PFH
total STS system = SUM PFH
D
- Lowest category of a module = category of whole
STS system
- Lowest DC of a module = DC entire STS unit
!
If the design of a unit is changed, the safety-related data may also
change.
22
SAFEMASTER STS/K-M10BM/K, MK01M/K / 17.06.20 de / 245A
M10BM/K
M10BBM/K,
MK01M/K
MKK01M/K
3
3
d
e
20
20
85 ...100
85 ...100
85 ...100
2 x 10
6
2 x 10
6
365
365
24
24
1
1
8760
8760
60 %
90 %
1 / year
1 / month
1 / month
+ ... PFH
D1
4
e
20
2 x 10
6
365
24
1
8760
99 %
Dn