4.15
Connection of the PHOTOCELLS B (both in closing and opening) 24 Vac
15
16 17
18
Power supply
RX Photocell
Receiver photocell.
N.C. contact
4.16
Connection of the PHOTOCELLS B - 24 Vac with phototest
15
16 17
18
19
Power supply
RX Photocell
19
20
21
22
23
20
21
22
23
Receiver photocell.
N.C. contact
24
25
Power supply
TX photocell
28
24
25
Power supply
TX photocell
-12-
The contact of the photocell's
receiver must be:
- clean (isolated from the po-
wer supply voltage)
- type N.C.
(normally closed)
If you are using several sets of
photocells the connection must
be done in series.
If the input PHOTO B is
not used put the
DIP 6 B in ON mode
29
30
31
The contact of the photo-
cell's receiver must be:
- clean (isolated from the
power supply voltage)
- type N.C.
(normally closed)
Technical manual