EB TECHNOLOGY START-S6XL BLOCK Notice D'emploi page 34

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

START-S6XL BLOCK
4.10
Connection of the commands "START" and "PEDESTRIAN"
16
17
18
19
By using the clamps no. 17 and no. 24 you can connect a TIMER to program the openings of the gate. The con-
tact of your timer must be a type N.O. and must stay in a close mode the whole time the gate remains opened.
If there is an opening command connection on the clamp no. 17, connect in parallel.
4.11
Connection of Elec. lock 12 Vac
Aside is the layout of the connection
of the 12 Vac elec. lock:
4.12
Power supply of ACCESSORIES
Below the layout of the connection for a correct power supply of the accessories. keep in mind that between
the clamps from no.19 to no. 30 there is a tension of 12 Vac
17
18
TERMINAL 18-19
Tension: 24 Vac
Max Absorption: 300mA
20
21
22
23
24
19
20
21
TERMINAL 19-30
Tension: 12 Vac
Max Absorption: 600mA
The connection of the command for pedestrian opening
25
can be realized on every button or contact as soon as it
is type N.O. (normally opened).
The connection of the opening command START can be
realized on every button or contact as soon as it is type
N.O. (normally opened). If you have several devices to
connect you need to connect them in parallel.
18
19
20
21
22
28
-10-
23
29
30
31
29
30
31
32
+
-
TERMINAL 31-32
Tension: 24 Vdc
Max Absorption: 100mA
Technical manual
32