EB TECHNOLOGY START-S6XL BLOCK Notice D'emploi page 33

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

START-S6XL BLOCK
4.6
Connection of Courtesy light
3
4
5
DIP 4 A - ON
ON
2
3
4
6
7
8
1
5
4.8
Connection of arrest devices STOP command
Connection of the STOP command:
Button: stops and inhibits temporarily the control unit until a
new command.
Switch: keeps the automation blocked until a new retrieval
is ordered.
If the STOP input is NOT
used put the DIP 6 B on ON.
You need to use any kind of button or contact provided it is type N.C. (normally closed)
to connect the safety devices. If there are several safety devices they have to be connected in series.
4.9
Connection of the LSO and LSC LIMIT SWITCHES
The picture shows the connection of both limit switches.
12
13
14
15
MOTOR 2
CLOSE
Light Group
230 Vac
CTS
10
9
16
17
18
19
20
OPEN
CLOSE
4.7
If you are using a piece of stiff wire instead of an an-
tenna, to obtain a 433Mhz frequency you have to cut
it off to 17 cm e connect it to the clamp no. 25
ONLY CONNECT THE ANTENNA AFTER THE
MEMORIZATION OF THE RADIO CODES IS DONE!!!
21
22
23
24
MOTOR 1
OPEN
-9-
Connection of ANTENNA
23
24
25
20
21
22
23
24
25
If the LSO or LSC inputs
aren't in use, follow the
instructions you find
in chapter n. 5.1
The contacts of the
limit switches must be type
N.C. (normally closed)
Technical manual
coaxial antenna
cable sock
25

Publicité