Using The Nose Cap - Hitachi NV 90AG Manuel D'instructions Et De Sécurité

Masquer les pouces Voir aussi pour NV 90AG:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
2 If nails are driven too deep, turn the adjuster to the
shallow side.
Adjustments are in half-turn increments.
Turn Adjuster
2
Too Deep
If nails are driven too shallow, turn the adjuster to the
deep side.
Turn Adjuster
2
Too Shallow
3 Stop turning the adjuster when a suitable position is
reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR EYE PROTECTION.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.

USING THE NOSE CAP

● Disconnect the air hose from the nailer
before attaching or removing the nose cap.
If you like to protect the surface of workpiece against
scratches or markings made by the push lever, attach the
accessory nose cap to the push lever.
1 DISCONNECT AIR HOSE FROM NAILER.
2 Put the nose cap to the toe of the push lever.
NOTE:
● The nose cap may reduce nailing depth due to its
thickness. Re-adjustment of nailing depth is required.
18
Flush
Flush
WARNING
Push Lever
Nose Cap
Nose cap can be removed from the push lever using a
screwdriver or thin rod.
Push lever
Nose cap
Nose cap can be stored on the magazine as shown below.
Magazine
Nose cap
Nose
Do not connect
1
Hole
air hose
Protrusion (Inward)
Screwdriver

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nv 90ag sNt 65m2Nt 65m2 s

Table des Matières