Warnings" above.
Installation
Set-Up
Position equipment in the work area and make sure there is ample access to
the unit for filter maintenance.
Connect extraction hoses to the air inlets.
Connect the power cord to the equipment and to a grounded wall socket.
Follow operating and maintenance procedures stated in this user guide.
Operation
Do not operate the equipment without installing filters. Unfiltered air
contaminants may damage motor bearings and other components. Use only factory
recommended filters.
Models with Analog Control
Toggle switch (1) to turn the unit
ON / OFF
Monitor the gauge (2) for filter
condition
Models with Digital Control
Display Functions:
(1) Start / Stop
(2) Operation Indicator Light
o
Green: Unit is on. No alert.
Blinking Green – Orange: Pre-
o
Alarm is On
Blinking Green – Red: Alarm is
o
On
o
Blinking Red: Pump is OFF /
Alarm is On / Auto-shut-down
is ON.
(3) Particulate Filter Condition – blockage in %
(4) Exhaust Air Temperature
(5) Setup Button
(6) Time to Service
(7) Actual Run Time
(8) Particulate Filter Condition – Bar Graph
(9) Quick View Button of Set Parameters
All alarms are "visual". No acoustical alarms. In an alarm condition one or several
LCDs (3) (4) (6) or (7) will be blinking to indicate which alarm flag is ON.
Press (1) to turn the equipment ON / OFF
Monitor the following parameters
o
LED (2) for any ALERT conditions.
o
Particulate filter condition (3) and (8) for any alarm condition
2
2
1
8
9
4
1
3
4
6
7
5