DCN Discussion System
5.
Part of system not working
Eng
Possible cause
Interrupted trunk-line cabling.
Solution
Check the trunk-line cabling connections between the units and the CCU.
11.Technical data
Electrical data
11.1 Combined units
Delegate/interpreter microphones with transmission links to interpreter/delegate
headphones and auxiliary outputs.
General
Typical frequency response
Total harmonic distortion at overload
Crosstalk attenuation
11.2 System Electrical and Electro-acoustical characteristics
Nominal input level
Overload input level
Automatic gain reduction at Overload
input level (not for PA-floor output)
Automatic gain reduction with:
- 2 microphones on
- 4 microphones on
Loudspeaker gain control
11.3 Interface data
LBB 3500/.. Central Control Unit
Power consumption
Line in/outputs
Recorder input/output
Mains voltage
Instructions for use
:
125 Hz (-8 dB) - 14.000 Hz (-8 dB)
:
< 1 %
:
> 80 dB
:
85 dB SPL
:
110 dB SPL
:
- 30 dB (interpretation channels)
- 18 dB (loudspeaker channel)
:
3 dB
:
6 dB
:
off +13 steps of 1.5 dB
:
320 W (VA) at max. load
:
-18 dBV/ +12 dBV (nominal/maximum)
:
-33 dBV/ -3 dBV (nominal/maximum)
:
105, 115, 125, 220, 230, 240 Va.c, 50/60Hz
16