Festo Soft Stop SPC11 Serie Guide De Référence Rapide page 17

Masquer les pouces Voir aussi pour Soft Stop SPC11 Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
3
Fitting and pneumatic installation
Mount the SPC11 on a flat surface. Use at least 3 screws
(M4) to fasten it.
Compressed air / service unit
5 to 7 bar, dry, non−lubricated, 5 m filter cartridge.
S
For good positioning behaviour, the compressed air on
S
the MPYE−5−...: must not fluctuate more than ± 1 bar.
Sufficient standard flow (reference value: twice the
S
standard flow of the valve).
Use a microfilter if slight oil mist cannot be avoided.
S
Proportional directional control valve (type MPYE−5−...)
This should be fitted and connected up symmetrically
S
to the centre of the drive. If fitted to moving parts, the
MPYE−5−... must be mounted at right angles to the
direction of movement.
Fit silencers with large rated flow (e.g. U−1/8), length
S
of tubing max. 1 m.
Compressed air tubing and screw connectors
The tubing for the valve drive must be symmetrical.
S
With linear drives: tubing length = drive length