Télécharger Imprimer la page

To Stop The Heater; To Restart The Heater; Operation - Mi-T-M MH-0125-RM10 Manuel De L'opérateur

Publicité

Les langues disponibles

Les langues disponibles

3. Plug power cord into three prong, grounded extension cord and plug extension cord into three prong 20V
grounded outlet. The extension cord should be at least six feet long.
Extension cord wire size requirements are as follows:
6 to 10 feet (1.8 to 3 meters), use 18 AWG wire.
11 to 100 feet (3.4 to 30.4 meters), use 16 AWG wire.
101 to 200 feet (30.8 to 61 meters), use 14 AWG wire.
4. Push the Operation switch to the "High" or "LOW" position. The power indicator lamp will light and the heater
will start.
NOTE: The electrical components of this heater are protected by a fuse mounted in the PC board. If the heater fails to fire,
check this fuse first, and replace if necessary. Also check the power source to be sure that the proper voltage is being
provided to the heater.

To sToP The heaTeR

WaRnInG: Do noT DIsConneCT The PoWeR soURCe oR UnPlUG The PoWeR CoRD UnTIl
The CoolInG CYCle has been CoMPleTeD!
. Push the Operation switch to "OFF" position. Combustion will stop, and the Cooling Cycle (approx. 3
minutes in duration) will begin.
2. When Cooling Cycle is completed (fan stops running), it is safe to unplug the heater. Unplugging the heater
before the Cooling Cycle has ended may cause overheating, possible damage the heater and heat plate,
and will void the warranty.

To ResTaRT The heaTeR

. Wait ten seconds after cooling cycle has completed.
2. Push the Operation Switch to "High" or "LOW" position.
3. Be sure to follow all starting procedure precautions.
Kerosene Radiant Portable Heaters Manual

OPERATION

3

Publicité

loading