Flame Sensor: The heater uses a photocell to "see" the flame in the combustion chamber. Should the
flame extinguish, the sensor will stop electrical current and the heater will shut off.

VENTILATION

Risk of indoor air pollution. Use heater only in well ventilated areas. Always provide a fresh air opening in
the heated space of at least three square feet (2,800 sq. cm) for each 100,000 BTU/Hr. of heater output.
Provide a larger opening if more heaters are being used. As an example, a heater will require:
a two-car garage door open 6 inches, or
a single car garage open 9 inches, or
two thirty two inch wide windows open fifteen inches.

TO START THE HEATER

1. Fill the tank with kerosene until fuel gauge points to "F".
2. Be sure fuel cap is secure.
3. Plug power cord into three prong, grounded extension cord and plug extension cord into three prong
120V grounded outlet.
The extension cord should be at least six feet long.
Minimum extension cord wire size requirements are as
follows:
6 to 10 feet (1.8 to 3 meters), use 18 AWG wire.
11 to 100 feet (3.4 to 30.4 meters), use 16 AWG wire.
101 to 200 feet (30.8 to 61 meters), use 14 AWG
wire.
4. Turn thermostat control knob to desired temperature setting.
The setting range is from 40° F to 110° F. Push the Power
switch to the "ON" position.
If the heater does not fire, the thermostat may be set too
low. Turn the Control Knob to a higher setting until heater
fires. If the heater still does not start, push Power Switch
to "OFF", then back to "ON". If heater still does not fire,
see Troubleshooting Guide.
NOTE: The electrical components of this heater are protected by a
fuse mounted in the PC board. If the heater fails to fire, check
this fuse first, and replace if necessary. Also check the power
source to be sure that the proper voltage is being provided to
the heater.
NEVER
LEAVE
BURNING OR WHILE CONNECTED TO A FUEL SOURCE.
Note: Using Diesel fuel can cause excess soot production

TO STOP THE HEATER

Simply turn the Power switch to "OFF" position and unplug the Power Cord.

TO RESTART THE HEATER

1. Wait ten seconds after shutting off heater.
2. Turn the Power Switch to "ON" position.
3. Be sure to follow all starting procedure precautions.
Kerosene Portable Heaters Manual
HEATER
UNATTENDED
OPERATION
Thermostat Control Knob
Power Switch
WHILE
Lamp
Room Temperature
Display
Power Switch