Learning For Operation With Limit Switch; Learning For Operation With Encoder; Learning The Pause Time; Learning The Partial-Pedestrian Opening Time - O&O DEC-BT Manuel D'installation Et D'utilisation

Dispositif electronique de commande pour portes à un ou deux battants
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

To program the work time with the limit switches you need to fit the SF2M board on the DEC-BT control unit.
Set the dip switches on the SF2M board accordingly to obtain the operating mode required. Make sure the leaves are closed and hold
button P1 down for at least 3 seconds: the Prog LED will start flashing and leaf 1 will start to open. By pressing button P1 or START a
number of times (consequently providing pulses), the following sequences will be activated:
1st pulse of 3 sec.
2nd pulse:
FCA M1:
4th pulse:
FCA M2:
6th pulse:
FCC M2:
8th pulse:
FCC M1:
NB.: If you wish to eliminate the slowdown function in some phases, you need to wait for the leaf to reach the end-of-travel position without
pressing the button to activate the slowdown phase.
To program the work time with the Encoder you need to fit the SF2M board on the DEC-BT control unit.
Set the dip switches on the SF2M board accordingly (1-2 in ON).
Make sure the leaves are closed and hold button P1 down for at least 3 seconds: The Prog LED will start flashing and leaf 1 will start ope-
ning. By pressing button P1 or START a number of times (consequently providing pulses), the following sequences will be activated:
1st pulse of 3 sec.
2nd pulse:
3rd pulse:
4th pulse:
5th pulse:
6th pulse:
7th pulse:
8th pulse:
9th pulse:
NB. : If you wish to eliminate the slowdown function in some phases, you need to wait for the leaf to reach the end-of-travel position and
then press button P1 or START two times consecutively.
Hold button P3 down for more than 3 seconds until the programming LED lights up steady.
If you press button P3 within 3 seconds, the pause time will be cancelled.
If you wait, the programming LED will start to flash once every second.
The pause time count starts from this point and the time lapsed is saved by pressing button P3 again.
12. LEARNING THE PARTIAL - PEDESTRIAN OPENING TIME
The PED.S input can act as partial opening in the case of gates with double leaf or as pedestrian opening in the case of gates with 1 leaf.
12.1 LEARNING THE PAUSE TIME IN PARTIAL OPENING (2 LEAVES)
When the PED.S. input is activated for gates with double leaf, just leaf 1 is opened.
Seeing as the work time is already programmed, you can save the pedestrian pause time following this sequence:
- Hold button P2 down for more than 3 seconds and the programming LED will light up steady.
- If you press button P2 again within 3 seconds, the pause time will be cancelled.
- If you wait, the programming LED will start to flash once every second.
- The pause time count of the partial cycle starts from this point and the time lapsed is saved by pressing button P2 again.
12.2 LEARNING THE PEDESTRIAN OPENING TIME (1 LEAF)
For gates with single leaf, you can program the pedestrian opening, which in other words is a portion of the total cycle.
During the travel learning phase, you can also program the pause time following this sequence:
- With the gate closed, hold button P2 down for more than 3 seconds until the Prog.LED starts flashing and the leaf will start to open.
- Press button P2 or S.PED to stop the leaf.
- If you press P2 or S.PED again within 3 seconds, the leaf will close again without the pause time; if you wait on the other hand for the
PROG LED to start flashing, the pause time count will start.
- Press button P2 or S.PED to save the pause time and to close the leaf again.
- Before the leaf reaches the end-of-travel limit switch, press button P2 or S.PED to activate the slowdown function.
If the motor has a limit switch, the leaf will stop when it reaches FCC1, otherwise press button P2 or S.PED to stop the leaf.

10.1 LEARNING FOR OPERATION WITH LIMIT SWITCH

Double leaf
Leaf 1 starts to open
Leaf 1 opening slowdown
Leaf 1 end-of-opening and leaf 2 starts to open
Leaf 2 opening slowdown
Leaf 2 end-of-opening and leaf 2 starts to close
Leaf 2 closing slowdown
Leaf 2 end-of-closing and leaf 1 starts to close
Leaf 1 closing slowdown
Leaf 1 end-of-closing

10.2 LEARNING FOR OPERATION WITH ENCODER

Double leaf
Leaf 1 starts to open
Leaf 1 opening slowdown
Leaf 1 end-of-opening and leaf 2 starts to open
Leaf 2 opening slowdown
Leaf 2 end-of-opening and leaf 2 starts to close
Leaf 2 closing slowdown
Leaf 2 end-of-closing and leaf 1 starts to close
Leaf 1 closing slowdown
Leaf 1 end-of-closing

11. LEARNING THE PAUSE TIME

Single leaf (see point 9.2)
Leaf 1 starts to open
Leaf 1 opening slow down
End-of-opening and leaf 1 starts to close straight away
-------
-------
-------
-------
Leaf 1 closing slowdown
Leaf 1 end-of-closing
Single leaf (see point 9.2)
Leaf 1 starts to open
Leaf 1 opening slowdown
End-of-opening and leaf 1 starts to close straight away
Leaf 1 closing slowdown
Leaf 1 end-of-closing
- 18 -