  • Page 1 S90 ELECTRIC INDUCTION RANGES FOURNEAUX ÉLECTRIQUES À INDUCTION INSTALLATION- AND OPERATING INSTRUCTIONS page 3 INSTRUCTIONS D’INSTALLATION ET D’EMPLOI page 11 Doc. 62.9581.01_UL Edition 1 01.2006...
  • Page 2 Against wall - contre une paroi Free standing - isolé Connections - Raccordement Gas - Gaz Fig.1 INSTALLATION DRAWINGS - PLANS D'INSTALLATION Doc. 62.9581.01_UL...
  • Page 3 Free standing - isolé operated from both sides - ulilisable des deux côtés Connections - Raccordement Gas - Gaz Fig.1 INSTALLATION DRAWINGS - PLANS D'INSTALLATION...
  • Page 4 Doc. 62.9581.01_UL...
  • Page 5: Table Des Matières

    CONTENTS GENERAL INFORMATION ....................3 INSTALLATION INSTRUCTIONS ..................5 OPERATING INSTRUCTIONS .................... 9 SOMMAIRE INSTRUCTIONS GÉNÉRALES ..................11 INSTRUCTIONS RELATIVES À L'INSTALLATION ............13 OPERATING INSTRUCTIONS ..................17 62.9581.01_UL Page 1...
  • Page 6 Page 2 62.9581.01_UL...
  • Page 7: General Information

    GENERAL INFORMATION GENERAL INFORMATION INSTRUCTIONS FOR SAFETY AND USE SAFETY-CONSCIOUS WORKING INSTALLATION AND INITIAL OPERATION Touching the hotplates can cause burns. As soon as a crack in the surface becomes installation, adjustment initial visible, the equipment is to be disconnected operation of the appliance must be properly immediately from the power supply.
  • Page 8: Technical Data

    GENERAL INFORMATION TECHNICAL DATA Width Full sur- Power Depth face Voltage Height cooking Appliance type Appliances zones inch in kW 9CHG584126 WIWRAFQOOO 9CHG584127 WIXRAFQOOO 19.7 9CHG584128 WIWRAAQOOO 35.4 9CHG584129 WIXRAAQOOO 35.4 9CHG584130 WIWRABQOOO 9CHG584131 WIXRABQOOO 9CHG584132 WIWWAFQQOO 9CHG584133 WIXWAFQQOO 39.4 1000 9CHG584134 WIWWAAQQOO 35.4...
  • Page 9: Installation Instructions

    INSTALLATION INSTRUCTIONS II . INSTALLATION INSTRUCTIONS INSTALLATION ASSEMBLING TWO APPLIANCES The appliance is designed for connection to fixed lines. The appliances are suitable for setting up as single appliances or as a group of appliances. They can be set up freely in the room, side by side, at the side and/or at the back against a wall.
  • Page 10 INSTALLATION INSTRUCTIONS SIDEWALL (D) ASSEMBLING ON CASTORS (3c) Fig.2 Assemblage of sidewall The assembly kit contains two of each of the following: (3c) hexagonal screws M8x25 (1 / Fig.1), bolts with retaining rings (3c) (2 / Fig.1), mounting links (3 / Fig.1), hexagonal screws M8x16 with serrated washers and hexagonal nuts M8, hexagonal screws M5 with serrated washers (4 / Fig.2) and a fastening angle (5 / Fig.2).
  • Page 11 INSTALLATION INSTRUCTIONS FRONT PANELS (A) and (B) DOWNPIPE (3c) Fig.6 Front panel Unscrew screws (1 or 3). Also, in the case of a built-in oven, unscrew screws (2 and/or 4) on the inside of the oven. Pull the panel away forwards and downwards. CONTROL PANEL (C) Fig.
  • Page 12: Electrical Connection

    INSTALLATION INSTRUCTIONS ELECTRICAL CONNECTION CONNECTION TO THE POTENTIAL EQUALIZATION SYSTEM Each appliance is accompanied by a complete connection and The appliance is to be connected to a potential equalization wiring diagram enclosed. This contains full details of the system with a minimum conductor cross-section of 10 mm². technical specifications (electrical rating, voltage, amperage Use the appropriately marked terminal studs for this purpose etc.)
  • Page 13: Operating Instructions

    OPERATING INSTRUCTIONS III . OPERATING INSTRUCTIONS GENERAL Cooking pans with a diameter of less than 6.3“ (16 cm) must not be used. The appliance is used for boiling, searing, cooking, keeping warm and preparation. Depending on the type of range, the Warning: glass ceramic plate is equipped with two or four rings with an •...
  • Page 14: Shutting Down

    OPERATING INSTRUCTIONS STORAGE SPACE Never use corrosive substances for cleaning the floor under the appliance (e.g. hydrochloric acid). Clean the The storage space (Fig.12) is incorporated into the base unit. appliance with commercial cleaning agents. Recommended accessories: SHUTTING DOWN - Shelf holder (1) 2 off. - Shelves (2) 1 off.
  • Page 15: Instructions Générales

    INSTRUCTIONS GÉNÉRALES INSTRUCTIONS GÉNÉRALES CONSIGNES DE SÉCURITÉ ET D'UTILISATION TRAVAILLER EN TOUTE SÉCURITÉ On peut se brûler si l'on entre en contact avec INSTALLATION ET MISE EN SERVICE les plaques chaudes. Le montage, le réglage et la première mise en Dès qu'une fissure est visible en surface, service de l'appareil doivent s'effectuer confor- débrancher...
  • Page 16: Emballage

    INSTRUCTIONS GÉNÉRALES DONNÉES TECHNIQUES Largeur Surface Puis- sance Profondeur Modèle Voltage Hauteur Appareil PNC de l'appareil inch in kW 9CHG584126 WIWRAFQOOO 9CHG584127 WIXRAFQOOO 19.7 9CHG584128 WIWRAAQOOO 35.4 9CHG584129 WIXRAAQOOO 35.4 9CHG584130 WIWRABQOOO 9CHG584131 WIXRABQOOO 9CHG584132 WIWWAFQQOO 9CHG584133 WIXWAFQQOO 39.4 1000 9CHG584134 WIWWAAQQOO 35.4 9CHG584135 WIXWAAQQOO...
  • Page 17: Instructions Relatives À L'installation

    INSTRUCTIONS RELATIVES À L'INSTALLATION II . INSTRUCTIONS RELATIVES À L'INSTALLATION MISE EN PLACE ASSEMBLAGE DE DEUX APPAREILS Cet appareil est conçu pour être raccordé à des conduites fixes. Les appareils peuvent être montés individuellement ou en groupe. Ils peuvent être installés de façon indépendante, côte à...
  • Page 18: Socle En Acier

    INSTRUCTIONS RELATIVES À L'INSTALLATION PAROI LATERALE (D) ASSEMBLAGE SUR ROULETTES (3c) Fig.2 Montage du paroi latérale Chaque kit d'assemblage comprend respectivement deux vis hexagonales M8 x 25 (1 / Fig.1), des boulons avec circlip (2 (3c) (3c) / Fig.1), des éclisses (3 / Fig.1), des vis hexagonales M8 x 16 avec rondelles à...
  • Page 19: Panneau Avant (A) Et (B)

    INSTRUCTIONS RELATIVES À L'INSTALLATION SORTIE PANNEAU AVANT (A) et (B) (3c) Fig.6 Panneau avant Desserrez les vis (1 et 3 Fig.5, Fig.6). Si le four est encastré, desserrez Extrayez le panneau vers l'avant et le bas. Fig.8 Sortie PANNEAU DE COMMANDE (C) Les plans de travail avec sortie (fig.
  • Page 20: Branchement Électrique

    INSTRUCTIONS RELATIVES À L'INSTALLATION BRANCHEMENT ÉLECTRIQUE BRANCHEMENT AU SYSTÈME ÉQUIPOTENTIEL L'appareil doit être raccordé à un système équipotentiel dont la Chaque appareil est accompagné d'un schéma complet des section du conducteur est d'au moins 10 mm . Pour ce faire, connexions et du câblage reprenant les données techniques utilisez les boulons identifiés à...
  • Page 21: Operating Instructions

    OPERATING INSTRUCTIONS III . OPERATING INSTRUCTIONS GÉNÉRALITÉS cuisson, la zone chaude reste désactivée. Celle-ci ne sera pas réactivée automatiquement. Pour réactiver le système L'appareil permet de bouillir, saisir, cuire, tenir au chaud et de détection marmite, il faut que vous éloignez l'ustensile de préparer des aliments.
  • Page 22: Mise Hors Service

    OPERATING INSTRUCTIONS • Si vous avez déposé par mégarde des objets en plastique, ESPACE DE RANGEMENT des feuilles en aluminium, etc. sur les surfaces vitrocéra- L'espace de rangement (Fig. 12) est installé dans la partie miques chaudes et qu'ils ont fondu, procédez immédiate- inférieure de l'appareil.