Connections; Technical Features - Fermax iLOFT BUS2 Manuel D'installation Et Utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
iLOFT Monitor
iLOFT Monitor
iLOFT Monitor
iLOFT Monitor

CONNECTIONS

JP1=DATA
TERM
NO TERM
JP2=VIDEO
TERM
NO TERM
JP2 JP1
Bout
Bin
- F1 F2
T Ct A SEC -
Surface
- Audio + Video Communication Bus (polarity free)
Bin
- Monitor/Additional Telephone Connection
Bout
Connection to next monitor/telephone on the cascade.
Additional Functions (negative output «-»).
F1, F2:
Maximum current per F1 and F2 button: 150mA
T, -:
Call Button Connection for Doors to Residences.
When the video is activated from this terminal on the monitor, it generates a voltage of
CT
10Vdc (Auxiliary Camera Activation).
Call Extension Connection Ref. 2040.
A, -
Generates a voltage of 12Vdc for a period of 5 seconds when a call is received on
SEC
the monitor.
In cascade systems:
- Set up the JP1 switch in the NO TERM position on the first and mezzanine floor
monitors.
JP1:
- Set up the JP1 switch in the TERM position on the last monitor (top floor).
In distribution systems, set up the JP1 switch in the NO TERM position on all the
monitors.
- When there is only one monitor
position.
JP2 :
- If we have two monitors (or even a monitor and a telephone) the JP2 switch should be
set up in the TERM position on both terminals.

TECHNICAL FEATURES

Power Supply
Consumo
Operating Temperature
Humidity
TFT
Flat Screen. 3,5 Diagonal
Resolution:
Horizontal: 480 Line TV - Vertical: 234 Line TV
Video Signal: 4.5Vpp Modulated Signal
Flush mounted monitor dimensions
Pure flush mounted monitor dimensions
Surface monitor dimensions
Pure surface monitor dimensions
Page 20
Flush
per residence, set up the JP2 switch in the NO TERM
WITHOUT Induction Loop
on standby
making a call
with video
with audio and video
(Height x Width x Depth)
(Height x Width x Depth)
(Height x Width x Depth)
(Height x Width x Depth)
No Term
Bout Bin
Term
JP2 JP1
36 mA
350 mA
250 mA
390 mA
with audio at maximum
:
197 x 131 x 60 mm / 7,7" x 5,1" x 2,3"
: 197 x 131 x 59 mm / 7,7" x 5,1" x 2,3"
:
197 x 131 x 34,3 mm / 7,7" x 5,1" x 1,3"
:
197 x 131 x 33,3 mm / 7,7" x 5,1" x 1,3"
- F1 F2
T
Ct
A
SEC
24 Vdc
WITH Induction Loop
34 mA
490 mA
330 mA
634 mA
[5 , +40 °C]
[41, +104 ºF]
[0 - 90%]
-

Publicité

Table des Matières
loading

Table des Matières