INSTRUCTIONS
Operation Switch
The operation switch is located on the control panel
(see figure 1). To activate, turn the switch clockwise.
See that the switch is turned off before connecting or
disconnecting the plug.
Removing or Sercuring the Head
The head is held to the tank by two clamps. Lift the
clamps to release it from the tank (see figure 2).
Press in on the clamps to secure it to the tank.
Replacing the Filter Bag (see figure 3)
1. Remove the upper section of cleaner from the dirt
tank.
2. Carefully remove the filter bag connection from the
inlet fitting.
3. Close the filter bag connection with the slide.
4. Dispose of the filter bag in accordance with legal
regulations.
5. Place a new filter bag into the clean tank as
described in the instructions (printed on the filter
bag).
NOTE: Press the filter bag connection firmly on to the
inlet fitting.
CAUTION:
Before sucking in liquids,
remove the filter bag and check
the performance of the floater
(see "Maintenance" section).
When sucking in liquids, always
use a filter element or filter
screen (for order number see
assembly drawing #3). If foam
appears, stop work immediately
and empty the tank.
WARNING: If you use an extension cord, use
an extension cord with minimum
wire size 14 AWG. Do not use an
extension cord longer than 50
feet. Do not join tow extension
cords.
Clarke
®