PP Plus 36D/240D/401D
7 Screw down nut (6) and secure with multiple wrench (5).
NOTICE
• Mount the liner (8) pressing it slightly.
4.3.2 PA liner
NOTICE
• New and unused liners must be abridged to the actual length of the cable assembly.
• For PA liners with an outer diameter of 4.00 mm, the capillary tube in the distance
adaptor must be replaced with a guide tube.
• We recommend that you sharpen the PA liner to an angle of 40° before assembly using
the ABICOR BINZEL sharpener.
For use with aluminium, copper, nickel and stainless steels
1
11
10
1
Wire conduit
2
Central plug
3
Nut
4
Wire feed unit
Fig. 4
Shortening the PA liner
1 Sharpen the beginning of the PA liner (9) to approx. 40° with the ABICOR BINZEL
sharpener.
2 Slide PA liner (9) through the wire conduit (1) into the inlet nipple (11) until a noticeable
resistance is felt.
3 Slide clamp nipple (8), O-ring (7) and nut (3) on the PA-liner (9) and tighten the nut (3)
under tension.
4 Mark a PA liner (9) that is too long in front of the wire feed rolls.
BAL.0140 • 2018-10-15
40°
9
8
5
ABICOR BINZEL Cutter
6
Guide tube
7
O-ring
8
Clamp nipple
2
7
6
9
10 ABICOR BINZEL
11 Inlet nipple
4 Putting into operation
3
5
PA liner
Sharpener
4
EN - 9