Dometic A30-100C Mode D'emploi page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3. Turn thermostat knob (C) to the MAX position, press and hold down.
4. After approximately 10 seconds press knob (D) several times. (This could
take longer than 10 seconds if the unit has been out of operation for a
prolonged period or after replacing the gas cylinder. Cause: air in the pipes.)
5. After ignition, hold down knob (C) for a further 20-30 seconds before
releasing.
The flame can be controlled by flame indicator (B). The needle of the
galvanometer passes over into the green section.
6. Should no ignition occur, repeat the ignition process after 1 minute.
7. After sufficient cooling (approximately 5 hours), the thermostat position can
be set to a lower temperature. (Middle position) The thermostat will now
automatically regulate the set temperature.
12. Shutting down gas operation
-
Close gas cylinder or pressure regulating valve.
-
Energy selector switch (A) should be in position '0'
13. Food and drink storage
-
Foodstuffs and drinks should always be stored sealed in the unit. Thus,
changes in taste and smell are avoided.
-
Food and drink should be so placed in the cooler so as to allow air to
circulate freely.
-
Do not place hot food or drinks in the cooler!
-
Under no circumstances should inflammable liquids and/or gases be
stored in the cooler. Explosion hazard!
14. Defrosting and measures for prolonged
periods of disuse
A build up of too much ice on the evaporator hinders cooling of the unit and thus
reduces effectiveness. Therefore, it is recommended to defrost the mobile
max
position
A
Figure 5
C
middle position
(Fig. 2,6,7)
D
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rf60

Table des Matières