10. Faults
a) The equipment does not work
Check that the battery is charged and whether the charging unit is working.
b) An error code is displayed
Error code
E1
- The rechargeable battery is subject to
excessive current.
- Equipment defect
E3
- The equipment cannot start up be-
cause of, e.g. pressure load
- Equipment defect
E4
- The motor is overloaded
- Equipment defect
E5
- The equipment has been running for a
lengthy period of time and has become
hot.
E6
- The low-voltage protection has swit-
ched off the rechargeable battery.
E7
- Mechanical problem (gear unit)
E8
- Mechanical problem (motor)
E9
- The overvoltage protection has swit-
ched off the rechargeable battery.
If the equipment will not work in spite of the troubleshooting measures and the voltage supply being OK,
please send it to the customer service address below.
Anl_CE_CP_18_180_Li_E_Solo_SPK13.indb 23
Anl_CE_CP_18_180_Li_E_Solo_SPK13.indb 23
GB
Possible cause
- 23 -
Possible remedial measures
- Change the rechargeable battery
- Have the equipment start up in idle
mode
- Check whether the equipment can start
up unhindered
- Change the rechargeable battery
- Have the equipment start up in idle
mode
- Check whether the equipment can start
up unhindered
- Change the rechargeable battery
- Have the equipment start up in idle
mode
- Allow the equipment to cool for about 30
minutes. It will only run again when there
has been a signifi cant decrease in the
temperature of the equipment again.
- Change the rechargeable battery
- Charge battery
- Check whether the equipment can start
up unhindered
- Change the rechargeable battery
- Have the equipment start up in idle
mode
- Check whether the equipment can start
up unhindered
- Change the rechargeable battery
- Have the equipment start up in idle
mode
- Change the rechargeable battery
- Check the voltage of the rechargeable
battery (max. 21V)
11.04.2022 13:14:26
11.04.2022 13:14:26