Zanussi ZEI3921 Notice D'utilisation page 10

Masquer les pouces Voir aussi pour ZEI3921:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

(safety standards, recycling standards, elec-
trical safety standards etc.)
Warning! Risk of injury from electrical
current.
• The electrical mains terminal is live.
• Make electrical mains terminal free of volt-
age.
• If the fixing bracket is near to the terminal
block, do not let the connection cable come
in contact with the edge of the bracket.
Electrical connection
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug (if
applicable).
• The appliance must not be connected with
an extension cable, an adapter or a multiple
socket. There is a risk of fire.
• Do not let the power cable to heat up to a
temperature of more than 90° C. The cable
should be guided by means of clamps fixed
to the side of the cabinet, in order to avoid
any contact with the equipment beneath the
cooktop.
• Make sure that there is access to the mains
plug after the installation.
Electrical Requirements
Permanent electrical installation must agree
with the latest I.E.E. Regulations and local
Electricity Board regulations. For your own
safety the installation must be done by a quali-
fied electrician (e.g. your local Electricity
Board, or a contractor who is on the roll of the
National Inspection Council for Electrical In-
stallation Contracting [NICEIC]).
The manufacturer refuses to be held re-
sponsible, if these safety measures are
not abided by.
Supply connections:
This hob has to be connected to 230 — 240 V
( 50 Hz) electricity supply.
Before carrying out the connection, make sure:
1. The limiter valve and the electrical system
can take the appliance load (see the rating
plate)
10
2. The supply system is equipped with an ef-
ficient earth connection in compliance
with the current standards and regulations
3. The outlet or omnipolar switch used for
connection is easily accessible with the
appliance installed.
The appliance is supplied with a 3 core flexible
power cable requiring a 13 amp plug fitted
with a 13 amp or 3 amp fuse dependent on
the load. You must purchase and install the
plug.
The wires in the cord are coloured as follows:
Green and yellow
Blue
Brown
Replacement of the connection cable
1. Connect the green and yellow (earth) wire
to the terminal which is marked with the
letter 'E', or the earth symbol
oured green and yellow.
2. Connect the blue (neutral) wire to the ter-
minal which is marked with the letter 'N' or
coloured blue.
3. Connect the brown (live) wire to the termi-
nal which is marked with the letter 'L' and
is always connected to the network
phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly at-
tached to the outer sheath.
- Earth
- Neutral
- Live
, or col-
www.zanussi.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Zei3921iba

Table des Matières