Remote Activation and Deactivation of the Outputs
(BGSM-120 series only)
, , , , , CAUTION - The GSM connection must be established before the outputs can be activated/deactivated
remotely.
The Open Collector outputs can be set as Bistable (activation and deactivation takes place by means of 2 separate
commands) or Monostable (the output remains active for the ON time and returns to standby mode when this period has
elapsed). Moreover, every output can be programmed to provide a confirmation signal (an SMS programmed previously
if output activation/deactivation is performed via SMS, or a confirmation ring if output activation/deactivation is performed
via caller identification).
, , , , , For further information on the terms "Control string" and "User code" used in this section, please refer to
the "I/O" and "Options->Codes" sections of the "PROGRAMMING VIA PC" chapter.
Bistable outputs
Open collector outputs set as bistable can be activated in 2 ways:
1. By sending an SMS consisting of the User code between two # characters, the Control string (Control String can not
have initial blank spaces) and the characters "=ON#", as follows:
2. Through caller identification: in this case the output is activated at "cost-free" as the Communicator, after identifying the
caller, rejects the call and activates the output.
, , , , , We recommend the device is programmed with the Black list enabled (Options->Dial Options) and White list
disabled (Phonebook->White list) for the numbers you wish to use for this function.
, , , , , A bistable OC output can ONLY be deactivated by sending an SMS message consisting of the User code
between two # characters, the Control string and the characters "=OFF#",as follows:
, , , , , The default User code is '0001'; if you wish to change it, please refer to the section "Remote programming->Changing
the User code".
Monostable Outputs
Monostable OC outputs can be activated in 2 ways:
1. By sending an SMS consisting of the User code between two # characters, the Control string (Control String can
not have initial blank spaces) and the characters "=ON#","=ON#TonU#" or "=OFF#",as follows:
The "=ON#tonU#" option is parameter allows to set the ON Time from 1 to 86400 seconds, with 1 second steps. The ON
Time can be set by means of the Communicator's console software. "Ton" is the required value and "U" is the unit in hours
(H), minutes (M) and seconds (S), as shown in the following example:
#9876#HOUSELIGHT=ON#3600S#
#9876#HOUSELIGHT=ON#50M#
#9876#HOUSELIGHT=ON#3600#
38
#User code#String=ON#
#User code#String=OFF#
#Account code#String=ON#
#Account code#String=ON#TonU#
#Account code#String=OFF#
SMS
#9876#HOUSELIGHT=ON#
(example: #9876#HOUSELIGHT=ON#)
(example: #9876#HOUSELIGHT=OFF#)
Output operating mode
Bistable Activation
Active for 3600 seconds
Active for 50 minutes
Active as per software programming,
the set ON time does not apply
GSM/GPRS Alarm Communicators