Product features
The numbering of the components shown refers to the dia-
gram of the charger on the graphics page.
A)
(1) Battery
(2) Green battery charge level indicator
(3) Red battery charge level indicator
(4) Charging slot
A)
(5) Battery charge indicator
(6) Temperature monitoring indicator
(7) Cord wrap
A) Accessories shown or described are not included with the
product as standard. You can find the complete selection of
accessories in our accessories range.
Technical Data
Charger
Article number
Battery charging voltage
(automatic voltage detec-
tion)
Charge current
Permitted charging temper-
ature range of the re-
chargeable battery
ProCORE18V batteries:
Charging time at battery ca-
pacity, approx.
– 4.0 Ah
– 7.0 Ah
– 8.0 Ah
– 12.0 Ah
Standard batteries: Charging
time at battery capacity, ap-
prox.
– 1.3 Ah
– 1.5 Ah
– 2.0 Ah
– 2.6 Ah
– 3.0 Ah
– 4.0 Ah
– 5.0 Ah
– 6.0 Ah
Number of battery cells
Weight according to
EPTA-Procedure 01:2014
Protection class
A) not valid for article number 2 607 226 477
Bosch Power Tools
Operation
Start-up
Note the mains voltage! The voltage of the power source
u
must match the voltage specified on the rating plate of
the charger. Chargers marked with 230 V can also be op-
erated with 220 V.
Charging process
The charging process begins as soon as the mains plug for
A)
the charger is inserted into the mains socket and the battery
(1) is inserted into the charging slot (4).
Thanks to the intelligent charging process, the charge condi-
tion of the battery is automatically detected and then
charged up with the optimal charge current depending on
battery temperature and voltage.
In this way, the battery is treated with care and remains per-
manently fully charged when it is stored in the charger.
GAL 3680 CV
2 607 226 ...
What the display elements mean
V
14.4 – 36
Flashing green battery charge level indicator (2)
A
8.0
°C
0 – 45
Note: The charging process is only possible when the tem-
perature of the battery is within the permitted charging tem-
80% / 100%
perature range, see section "Technical data".
80 %
min
32 / 51
min
50 / 64
min
68 / 79
will be completed in the Long Life charging mode.
min
113 / 126
Continuously illuminated green battery charge level
80% / 100%
indicator (2)
min
10 / 25
The battery can then be removed for immediate use.
min
10 / 25
When there is no battery connected, the continuous light of
min
15 / 30
the battery charge level indicator (2) indicates that the
min
15 / 30
mains plug is plugged into the mains socket and that the
min
20 / 35
charger is ready to be used.
min
25 / 35
Continuously illuminated red battery charge level
min
35 / 45
indicator (3)
min
35 / 55
4 – 30
kg
0.82
data". The charging process begins as soon as the permitted
A)
temperature range has been reached.
/ II
The rapid-charging procedure is indicated by
flashing of the green battery charge level in-
dicator (2). The battery can be removed at any
time and used.
Once approx. 80% of the battery capacity has
been reached, the flashing of the green battery
charge indicator slows down. The rapid-char-
ging process is now completed. If the battery
remains in the charger, the charging process
The continuous light of the green battery
charge level indicator (2) signals that the bat-
tery is fully charged.
The continuous light of the red battery charge
level indicator (3) shows that the temperature
of the battery is outside of the permitted char-
ging temperature range, see section "Technical
1 609 92A 5F9 | (22.10.2019)
English | 5