Pag. 22 di 40
E
N
To obtain a correct movement of the leaf gate it is necessary to respect the measures (to see the TABLES of the measures on the following page).
G
L
Column attachment
I
for KING operator
S
(code CCA1293 - CCA1294)
H
If there is an iron pillar you can weld the attachment directly. If there is a cement pillar, you
can use the fixing plate which is fastened with 4 Fischer-screws of Ø 8 mm. (Fig. 3-4).
In the case you have a wall parallel with the open gate, you must provide a niche in which
to place the operator.
Column attachment
for KING L operator
(code CCA1370 - CCA1319)
To obtain a correct movement of the leaf gate it is necessary to respect the measures.
If there is an iron pillar you can weld the attachment directly.
If there is a cement pillar, you can use the fixing plate as in Fig. 6 which is fastened with
4 Fischer-screws of Ø 8 mm.
There is also the possibility to cement the attachment welding an anchor at its base Fig.
7.
Naturally you have to respect predetermined fixing measures.
Afterwards you must weld the other actuator's attachment to the gate (Fig. 8).
In the case you have a wall parallel with the open gate, you must provide a niche in which
to place the operator.
COL
Column attachment
KING
Z
Y
S1
X
S2
S3
FIXING THE ACTUATOR ATTACHMENT TO THE COLUMN
Fig. 9
Fig. 3
Fig. 5
Fig. 7
ANT
Leaf attachment
KING
A
B
Fig. 4
Fig. 6
Fig. 8
FIXING THE OPERATOR
ATTACHMENT TO THE GATE
(to see the TABLES of the measures on
the following page).
Weld the base at the right height (Fig. 10).
Fix the KING and try several times to open and
to close the gate, controlling that the
screwcover does not touch the moving gate.
Fig. 10
ANT KING L
Leaf attachment KING L
C
D

Publicité