FILTRATION
Press the
FILTER button to turn the function on/off. The light turns to green when the function is activated.
FILTER
FILTER
NOTE: The filtration system will automatically start when the heating, Ozone or UVC sanitizing system is activated.
NOTE: After turning off the heating system, the filtration system will automatically stop in 30 seconds.
Filter Cartridge Cleaning Reminder: When the FILTER button is flashing or displays red, the filter cartridge must be cleaned or replaced. Once
this has been done, press the Filter button for 3 seconds to reset the reminder.
BUBBLE MASSAGE
BUBBLE button to turn the function on; hold down the BUBBLE button for 3 seconds to turn the function off. The BUBBLE button
Press the
BUBBLE
BUBBLE
displays green when activated.
The bubble setting can be adjusted to three different levels. The default setting is at level 2 (500W). Press the BUBBLE button to switch the
setting to level 3 (720W). Press it again to switch to level 1 (300W).
IMPORTANT: Do not turn on the massage system when the cover is attached. Air can accumulate inside the spa and cause irreparable damage
and bodily harm.
NOTE: The bubbling massage function will shut down automatically after every 20 minutes of operation as a safety precaution. This can be
reactivated after 10 minutes by pressing the BUBBLE button again.
HEATING TIMER
To set the number of hours FROM NOW when the heater will activate:
TIMER
1-99H
1. Press the
TIMER button to enter pre-setting mode. The button displays green.
TIMER
2. Pressing the
UP or
UP
activation (from 1 to 99 hours). The desired timer setting will remain on the LED display for 3 seconds to confirm the value.
To modify the timer setting: Press the Timer button again and use the UP or the DOWN button to adjust.
Cancel the setting: Press the TIMER button for 3 seconds.
NOTE: Activating the heating system or rebooting the spa will cancel the timer setting.
UVC SANITIZER
Press the
UVC button to turn the UVC sanitizing system on/off. When the light above this button is green, the UVC sanitizing system is
activated.
OZONE
Press the
OZONE button to turn the function on/off. The OZONE button displays green when the function is activated. The Ozonator will
shut down automatically after operating for 2 hours.
NOTE: For your own safety, do not bathe in the spa when the OZONE function is turned on. The OZONE function cannot be turned on when the
JET or BUBBLE function is on.
Celsius/Fahrenheit Toggle Button
The temperature can be displayed in either Celsius or Fahrenheit. Press the
DOWN
options.
3s
SAFETY LOCK
+
UP
DOWN
Press the
UP and
3s
UP
disabled and the spa retains all previous settings.
DOWN button will cause the LED to flash. While it is flashing, you can adjust the number of hours before heater
DOWN
DOWN buttons at the same time for 3 seconds to lock/unlock the controller. In safety lock mode, the controller is
DOWN
DOWN button for 3 seconds to toggle between the two
DOWN
12