SECURITY DISTANCES
From NOT combustible object :
•
A > 400 mm
−
From combustible object and from principal wall in reinforced concrete :
•
A > 800 mm
−
The minimal distance among the top of the appliance and any flammable object over it is
•
1.5 meter.
1.4 Connection
Before connecting the appliance, check the technical data reported in the technical plate (
•
Chap. 4 ) and control that it correspond to the ones required in the order.
All heating biomass equipments, especially wood burning appliances, have to evacuate
•
the combustion products in a flue, built in conformity with the normatives in force.
The following instructions describe „ informations for a good installation „ and refer to a
•
normative in force but they are not to be consider exhaustive for installations laws.
COLLAR EXHAUST FUMES ASSEMBLY
Place the collar over the plate (Fig.1) and fix it
•
to the plate employing the enclosed screws.
B > 100 mm
C > 100 mm
B > 200 mm
C > 200 mm
29/124
IT IT IT IT- - - - GB
GB- - - - FR
FR- - - - ES
GB
GB
FR
FR
D>1000 mm
D> 1500 mm
Mod. 703T-I 703T-IL
Valid for all Model - Measure from
external side of the equipment
Mod. 703T-G 703T-GL
ES- - - - DE
DE mod. 703T
ES
ES
DE
DE
Exhaust
fumes collar
Radiant
plate
Plate
frame