3.2 Ordinary maintenance (by qualified staff)
EVERY YEAR IS RECOMMENDED THE FOLLOWING OPERATIONS
MAINTENANCE:
Complete check up of the appliance by qualify staff.
Cleaning of exhaust gas and fumes tubes.
To check and eventually to replace of seal..
To check the flue seal.
To check integrity of the glass fire door versions available only on visible.
We recommend to stipulate a contract with an after-sales service
We recommend to execute a regular maintenance of the appliance, of the fumes exhaust
ducts and of the chimney. In case of a long time of non utilization of the appliance,
before lighting the appliance, verify that fume exhaust ducts and chimney are not
obstructed.

3.3 Accessories

The following accessories are supplied with the appliance :
To move residuals into the combustion chamber and to move
ash-drawer.
For warm parts
For handling the grate lifter

Possible failure and its solution

3.4
DEFECT
Windows fire door
and/or combustion
chamber are dirty of
soot.
CAUSE
− Low draft <10 Pa.
− Wrong regulation.
− Too much combustible
introduced.
− Combustible with high
humidity level.
− Not good quality
combustible.
49/124
IT IT IT IT- - - - GB
GB- - - - FR
FR- - - - ES
ES- - - - DE
DE mod. 703T
GB
GB
FR
FR
ES
ES
DE
DE
SOLUTION
− Check that the exhaust fumes
tube is not obstructed.
− Modify the flue : increase the
section, the height, verify the
isolation. Eliminate or reduce to
the minimum horizontal sections
and curve. Verify the section and
the height of the chimney cap
(see reflux zone)
− See charter "Regulations" and
"Fuel to be utilized"
− Reduce the quantity of fuel.
− Use dry and weathered wood
only.
− Read charter "Combustibile".