Compact 190
Connecting the device
A properly earthed socket outlet with earthing contact must be used for connection. The connection must be equipped
with a residual current protective device with INF ≤ 30 mA.
Setting up the unit
When working indoors:
Vapors containing solvents may not be allowed to build up in the area of the device.
Setting up the unit on the side a way from the sprayed object.
A minimum distance of 5 m between the unit and spray gun is to be maintained.
Danger
When working outdoors:
Vapors containing solvents may not be allowed to blow toward the unit.
Note the direction of the wind.
Set the unit up in such a way that vapors containing solvents do not reach the unit and build up there.
A minimum distance of 5 m between the unit and spray gun is to be maintained.
Maintenance and repairs
Before carrying out any work on the device, relieve the pressure and unplug the power plug from the socket.
Danger
Cleaning the unit
Danger of short circuit through penetrating water!
Never spray down the unit with high-pressure or high-pressure steam cleaners.
Danger
Cleaning units with solvents
When cleaning the unit with solvents, the solvent should never be sprayed or pumped back into a container
with a small opening (bunghole). An explosive gas/air mixture can be produced. The container must be
earthed.
Do not clean the device or accessories with ammable solvents with a ash point below 21 °C.
Danger
Earthing of the object
The object to be coated must be earthed.
Thermal release
The device is equipped with a thermal release which disconnects the device in case of overheating. In this case switch the device
o , turn the selector switch to the PRIME position (vertical), remove the mains plug and allow device to cool down for min. 30
minutes. Eliminate the cause of heating, e.g. slots for air intake covered.
1 Pressure regulator
3 Inlet valve pusher
5 Telescopic handle
7 Nozzle holder
9 ON / OFF Switch (0 = OFF, I = ON)
11 Filter red (1 unit) for spray nozzle 310
Filter white (2 units) for spray nozzle 419*
13 High-pressure hose
15 Inlet lter
17 Holder for paint container
19 Oil
* second lter pre-installed in gun
Coating Materials Suitable for Use
Dispersion and latex paints for interior use.
Water-based and solvent-containing lacquers and glazes. Paints, oils, release agents, synthetic enamels, PVC lacquers, undercoats,
Description (Fig. 1)
2 Hose connection
4 Hose holder
6 Spray Gun
8 Paint nozzle 310 (purple) and dispersion nozzle 419 (red)
10 Selector switch
12 Tool box
14 Return line
16 Suction hose
18 Automatic lubricator (button to lubricate pump)
20 Operating instructions
GB
19