7.
Drill the inflow and outflow with a DN 100 core
drill (with a diameter of 124 mm).
9.
Slide the outflow pipe through the outflow hole
from the inside.
11.
Depending on the tank size, the length of the jack
must be adjusted by moving the jack base. The
rough position is specified on the jack. The exact
height is to be determined inside the tank.
4. Assembling the set-up kit
De-burr the hole. Insert the DN 100 lip seal. In the
case of the outflow, the direction of the feed-
through must be from the inside out. Affix the "Out-
flow" sticker.
The jack base must be turned depending on the
tank size. The specified tank size on the base must
be the same as on the jack.
2700
4800
6500
Assemble the jack and sampler. To do this, push
the jack outflow into the sampler hole.