OPERATION
Controls
The hood is operated using the slide controls
under the bottom of the hood.
The light switch turns the lamps on and off.
The blower switch :makes it possible to select
the motor operating speed. Position 0: motor
off.
The pilot lamp lights up whenever the blower
is on.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF with its switch.
If you must stop the blower, do it from the main electrical panel.
HALOGEN BULBS
This range hood requires two halogen bulbs
(Type GU10, MR16 shielded, 120V, 50W).
ALWAYS SWITCH OFF THE ELECTRICITY
SUPPLY BEFORE CARRYING OUT ANY
OPERATIONS ON THE APPLIANCE.
1. Remove the grease filters.
2. Remove the metal grille by turning the (2)
knobs counterclockwise.
3. Loosen the ring nut by turning it
counterclockwise.
4. Loosen
the
counterclockwise; pull the bulb downwards
to remove. CAUTION: BULB MAY BE
HOT!
5. Replace with Type GU10, MR16 shielded,
120V, 50W halogen bulb.
bulb
by
turning
- 9 -
LIGHT
SWITCH
PILOT LAMP
GREASE FILTERS
it
BLOWER
SWITCH
KNOB
METAL GRILLE
BULB
RING NUT