References, Symbols And Abbreviations; Safety Instructions; Display - Watts Industries Climatic Control-H Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. REFERENCES, SYMBOLS AND ABBREVIATIONS

For better understanding in this document references are used in the form of symbols and abbreviations, which are
described below.
Reference to further documents
Important information and application hints
Safety information or
Important information about functions
OK-button (OK)
Control button Left (◄)
Control button Right (►)
Plus button (+)
Minus button (-)

3. SAFETY INSTRUCTIONS

Before starting work disconnect power supply!
All installation and wiring work related to the controller must be carried out only when de-energized.
The appliance should be connected and commissioned by qualified personnel only. Make sure to ad-
here to valid safety regulations, in particular to VDE 0100 (German standard governing power installa-
tions of nominal voltages ≤ 1000 VAC).
The controllers are neither splash- nor drip-proof. Therefore, they must be mounted at a dry place.
Do not interchange the connections of the sensors and the 230V connections under any circumstances! Inter-
changing these connections may result in life endangering electrical hazards or the destruction of the appliance
and the connected sensors and other appliances.

4. DISPLAY

Operating modes
1:
Keyboard is locked
2:
Service Installation Menu
3:
Manual operation / program override active
4:
(display of temperature offset)
a) display temperature (°C / °F)
5:
b) display time (12 h / 24 h)
Type of temperature displayed
6:
a) Water temperature
b) Outside temperature
c) Room temperature (if RF room thermostat con-
nected)
Program graphic of the current day
7:
Comfort temperature
Reduced temperature
Pump indicator
8:
Mixing valve activity indicator
9:
 Valve actuator is opening
 Valve actuator is closing
10: Current day of the week (1 = Monday; 7 = Sunday)
11: RF reception indicator
12: a) Symbol temperature indication in °C / °F
b) Symbol AM / PM if 12 h mode
13: a) Outside temperature (°C / °F)
b) Time (12 h / 24 h)
PPLIMP2350Bb
(optional).
Floor heating
FBH
Radiant heating (general)
FH
Hydraulic control unit with pump and mixing
FRG
valve
Manifold
HKV
Installation and operation manual
MuB
Temperature limiter
TB
Circulation pump
UWP
Boiler / heat generator
WE
2
3
4
5
6
7
8
9
Details Pos. 6
a
b
c
Fig.3
GB
1
Fig.2
86 mm
47 mm
OK
page 27
10
11
12
13
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Flowbox-control-h

Table des Matières