Time And Date Adjustment; Rf Installation; Starting - Watts Industries BT DPRF-01 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
- Now your thermostat will propose you to adjust the
current time and date.
2.2

Time and Date adjustment

Each time a value blinks, you can adjust it with the
(-) and (+) keys, once the value is chosen, validate
it with the (OK) key. The thermostat will jump
automatically to the next value.
Note: you can always come back to the previous
value by pressing the escape key (
List order of the time and date adjustments:
Time and day:
Adjustment of the hours,
Adjustment of the minutes
Adjustment of the day (1 = Monday)
Date:
Adjustment of the day number
Adjustment of the month number (01 to 12)
Adjustment of the year (Century)
Adjustment of the year
13
thermostat has received. (The heating is generally
showed by a Red LED).
- Now return to the thermostat and switch off it.
Check on the receiver again if it's also switched off
(The red LED must be turned off)
If the RF signals were received correctly,
o
adjust your setting temperature as you want.
If the RF signals weren't received correctly,
o
check the installation (Receiver position,
distance...)
* To make the installation easier it will be better to
have the thermostat near to the receiver during the
configuration mode. (A minimal distance of >
1meter must be respected)
16
Then the message "Save" and blinking green LED
appears, press (OK) to validate the adjusted time
and date.
You can always reach the time and date
adjustments, by pressing and maintaining the
edition ( ) key during 2 seconds in normal
operating modes.
2.3
- First of all to configure your thermostat with the
).
receiver, you must put your receiver in « RF init ».
mode. (please refer to the receiver leaflet for this,
only the RF receiver of the same range are
compatibles)
- Now on the thermostat press and maintain the
edition key ( ) during 10s, then the parameter «
ini » must be display.
2.4
The thermostat is now ready to works.
The default working mode will be automatic
with a standard built-in program "P1".
Monday to Friday
20°C
18°C
07:00
Saturday & Sunday
20°C
18°C
08:00

RF installation

14

Starting

09:00
17:00
23:00
23:00
17
The thermostat will send now the radio
configuration signal to the receiver.
- On the receiver check the good reception
(generally showed by a green LED blinking). Once
the configuration between the receiver and the
thermostat made, press on the escape key (
come back to the main screen.
- Now you can check the RF distance, go to the
room which must be regulated. Put your thermostat
on the final position (On the wall or table...), then
put the thermostat in Comfort mode (setting
temperature position 37°C). Close the door and go
to the receiver to check if the new status of the
15
Note:
You can customise your program as you want, See
the next part "Working mode definition" chapter
"Program" for more explanation.
Curent stage
of the program
Curent time
At any time, when the backlight is extinct, press the
(OK) key to lit-up the backlight,
and then press another time the (OK) key to show
the current setting temperature.
18
) to
Program
followed

Publicité

Table des Matières
loading

Table des Matières