When the appliance is in operation care
■
must be taken that the ventilation vents
are not covered over or closed.
No mechanical devices or synthetic mate-
■
rials other than those recommended
must be used to accelerate defrosting.
No liability will be accepted for any pos-
■
sible damage if the appliance is used for
any other purpose, incorrectly operated,
or not repaired by a professional techni-
cian. In such cases the guarantee and
other liabilities are rendered null and
void.
If the connection cable of the appliance
■
is damaged it must be replaced by the
manufacturer or by his customer service
or by a similarly qualified person to avoid
any liability.
Warning: do not operate any electrically-
■
driven devices inside the foodstuff com-
partment.
Operating and Control Panel
M ain switch on / off:
1
Entire appliance: on / off.
Child safety: the switch must be pressed
for at least 3 seconds.
T emperature indicator:
2
A value of the average temperature over
the last 2 hours is shown.
T emperature setting:
3
Two buttons: + button warmer, - button
colder. Press the switch for at least
3 seconds.
R apid cooling button:
4
Press the switch for 3 seconds. The appli-
ance cools down first to 2 °C for 36 hours
in the cold room, and then back to the
set temperature. Normal position: 5 °C.
4
5
2
3
@1
25