Handling The Nails; Removing The Nails - Hitachi NP 35A Manuel D'instructions Et De Sécurité

Micro pinnel
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Nose
Outlet
2
Arrow
Nose cap
Allen wrench for
M4 screw
Nose cap

REMOVING THE NAILS

● Before removing the nails, be sure to remove
your fi nger from the trigger and lock lever,
and disconnect the air hose.
(1) When 15 or more nails remain
○ Depress the stop lever and pull out the magazine
cover.
○ Remove the nails from the magazine.
(2) When fewer than 15 nails remain
○ Remove the nose using the 3 mm Allen wrench stored
in the back-end of the magazine.
○ Remove the nails from the guide surface of the blade
guide.
(See section 1 of "MAINTENANCE AND INSPECTION"
on page 17)
NOTE
When fewer than 15 nails remain, use caution as it is
hard to see the remaining nails in the blade guide.
16
1
Disconnect air
hose
Nose cap
WARNING

HANDLING THE NAILS

NOTE
○ Handle the nails carefully.
If nails are dropped, the connection may break. Using
nails in this condition may cause mis-feeding and
jamming.
○ Do not expose the nails to the outside air or to direct
sunlight for long periods as this may lead to rusting or
faulty connection of the nails. When not in use, keep
the nails in the box.